Sign In | Join Free | My isp.org.cn |
|
Brand Name : AIP
Model Number : AIP886X
Certification : CE/ISO9001
Place of Origin : China
MOQ : 1 set
Price : Negotiable
Payment Terms : L/C, T/T
Supply Ability : 50 sets per quarter
Delivery Time : 45 working days
Packaging Details : Export standard package
Machine : BLDC motor FCT test machine
Test station : 1/2/3 optional
Color : Gray
Power supply : 220/230V 50/60Hz
Warranty : 12 months
Brushless motor FCT testing machine/ BLDC motor testing
1. Machine description
This series of products, applied in FCT test of BLDC motor in the product of automobile, air conditioner, fan, blower, power tool etc, are able to test electrical performance of FCT accurately. The testing system is composed of test stand, IPC, test unit, system software and functional modules. Start the system, all set tests will be performed and displayed test data, which could be uploaded to MES. Display OK/NG test result with light and volume remind.
2. Machine feature
3. Test item
Load performance, Hall, phase loss
4. Technical parameters
Model | AIP886X series |
Test product | Brushless DC motor FCT |
Test station | Single/dual/three test station (optional) |
On-load | |
Voltage measuring range | Vm:DC 20.0~400.0V |
Voltage measuring precision | ±(0.5%×display value+1 digit) |
Current measuring range | Im: 0.01-2.00A |
Current measuring precision | ±(0.5%×display value+2 digit) |
Power measuring range | 1.0~300.0W |
Power measuring precision | ±(0.5%×display value+2 digit) |
RPM measuring range | Read the FG or Hall signal |
On-load setting range | 0.10~0.75Nm |
Rotation | CW, CCW, still |
Hall | |
High voltage range | 3.0~18.0V |
High voltage precision | ±(1%×display value+1 digit) |
Low voltage range | 0.0~18.0V |
Low voltage precision | ±(1%×display value+1 digit) |
Frequency | 1 ~ 599Hz |
Duty cycle | 0.1-99.9% |
Phase loss | |
Phase loss | Detect loss phase or not |
Other | |
Vsp power output range | DC 1.00~18.00V |
Vsp power output precision | ±(0.5%×setting value+1 digit) |
Vcc power output range | DC 1.0~18.0V |
Vcc power output precision | ±(0.5%×setting value+1 digit) |
Power on/off sequence | Power on sequence: Vcc-Vm-Vsp, Power off sequence: Vsp-Vm-Vcc Power off time and sequence can be set |
PWM signal output range/precision | Voltage: 1.00~18.00V ±(0.5%×setting value+1 digit) Frequency: 1KHz, 2KHz, 4KHz, 8KHz, 20KHz (optional other frequency) |
5. Software reference picture
![]() |